Freescale-semiconductor StarCore SC140 Bedienungsanleitung Seite 413

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 760
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 412
BRA
SC140 DSP Core Reference Manual A-99
BRA Branch (AGU) BRA
Description
Status and Conditions that Affect Instruction
None.
Status and Conditions Changed by Instruction
None.
Operation Assembler Syntax
PC + displacement PC
BRA <label
BRA >label
BRA >label
BRA <label
Causes program execution to continue at location PC + displacement. The displacement, calculated by the
assembler and linker, is a two’s complement integer that represents the relative distance from the current
PC to the destination label. The assembler determines if the PC relative displacement is a short branch
(<label [–2
10
displacement < 2
10
, W]) or a long branch (>label [–2
20
displacement < –2
10
, W and 2
10
displacement < 2
20
, W]).
Seitenansicht 412
1 2 ... 408 409 410 411 412 413 414 415 416 417 418 ... 759 760

Kommentare zu diesen Handbüchern

Keine Kommentare