HCS08 On-Chip DBG Module
Trace Component Window
534
Microcontrollers Debugger Manual
Figure 23.35 Trace Window - Context Menu Options
Selecting Show Location in the Trace window causes a context sensitive menu to appear
in Source and Assembly window the frame matching source and assembly code.
Graphical Display
You can select this display mode when selecting Graphical in the Trace window context
sensitive menu. It provides a graphical representation of the same information.
Figure 23.36 Trace Window - Graphical Display
Textual Display
This display mode can be select when selecting Textual in the Trace window context
sensitive context menu, when using Instruction Triggers
and Memory Access Triggers are
used. This display mode is rather useless for the DBG user interface, as no read/write
accesses are recorded at the same time than program change of flow information by the